| Product name | Human TSG101 ELISA Kit |
| Synonyms | ESCRT-I complex subunit TSG101, TSG 10, TSG 101, TSG10, VPS 23 |
| Reactivity | Human |
| Host / Isotype | United States |
| Tests | 1 X 96 well plate |
| Sample type | Serum, Plasma, Cell lysate |
| Assay type | Sandwich |
| Sensitivity | 0.03 ng/mL |
| Range | 0.156-10 ng/mL |
| Tested applications | Sandwich ELISA |
| Gene ID (NCBI) | 7251 |
| Sample Type | Average Range |
| Human serum | 106% 94%-115% |
| Cell lysate | 90% 70%-106% |
| Sample | n mean ( ng/mL ) SD CV% |
| 1 | 16 5.30 0.35 6.55 |
| 2 | 16 1.33 0.14 10.70 |
| 3 | 16 0.55 0.05 8.50 |
| Storage Instructions | All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. |
TSG101 (tumor susceptibility gene 101 protein) is a multi-structural domain protein that is widely expressed in a variety of cells and is involved in a variety of intracellular processes. It plays a key role in endoplasmic reticulum sorting, membrane receptor degradation, and the final stages of cytokinesis. TSG101 was initially defined as a tumor suppressor gene, but in some epithelial tumor cells, it exhibits tumor-promoting effects. In addition, TSG101 is involved in exosome secretion, positive regulation of ubiquitin-dependent endocytosis, and viral outgrowth. It also plays an important role in cell cycle regulation, cell survival, and maintenance of genome stability. Properties Storage Instructions All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. Synonyms ESCRT-I complex subunit TSG101, TSG 10, TSG 101, TSG10, VPS 23 FAQ 1、I have limited sample diluent. How should I handle samples requiring high dilution factors? Answer: We recommend performing a serial dilution. For example, if human serum requires a 1,000,000-fold dilution, you can use a three-step 100× dilution method as follows: Step 1: Take 2 uL of human serum and add it to 198 uL of sample diluent, mix thoroughly to obtain a 100-fold diluted sample. Step 2: Take 2 uL of the 100-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 10,000-fold diluted sample. Step 3: Take 2 uL of the 10,000-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 1,000,000-fold diluted sample. If further dilution is required, additional serial steps can be used. We do not recommend using any other solutions or water for dilution, except for the sample diluent we suggest. If your sample diluent is still insufficient, please contact our customer service for more sample diluent.