| Product name | Human/Mouse FLI1 ELISA Kit |
| Synonyms | FLI 1, FLI-1, Friend leukemia virus integration 1, Proto-oncogene Fli-1 |
| Reactivity | Human/Mouse |
| Host / Isotype | United States |
| Tests | 1 X 96 well plate |
| Sample type | Cell lysate |
| Assay type | Sandwich |
| Sensitivity | 0.05 ng/mL |
| Range | 0.156-10 ng/mL |
| Tested applications | Sandwich ELISA |
| Gene ID (NCBI) | 2313 |
| Sample Type | Average Range |
| Cell lysate | 88% 83%-91% |
| Sample | n mean ( ng/mL ) SD CV% |
| 1 | 16 5.03 0.32 6.36 |
| 2 | 16 1.19 0.10 8.40 |
| 3 | 16 0.60 0.05 8.33 |
| Storage Instructions | All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. |
FLI1 (Friend Leukemia Integration 1) is a proto-oncogene that encodes a member of the ETS (E-twenty-six) family of transcription factors. The FLI1 gene was initially identified as a common site of integration for the Friend murine leukemia virus, leading to erythroleukemia in mice. As a proto-oncogene, aberrant expression or activation of FLI1 can drive tumorigenesis. It is most famously implicated in Ewing's Sarcoma, a malignant bone and soft tissue tumor affecting children and young adults. Paradoxically, in certain contexts like some forms of T-cell acute lymphoblastic leukemia (T-ALL) and breast cancer, FLI1 can act as a tumor suppressor, where its loss or downregulation promotes cancer progression. This highlights the context-dependent nature of FLI1's function. Properties Storage Instructions All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. Synonyms FLI 1, FLI-1, Friend leukemia virus integration 1, Proto-oncogene Fli-1 FAQ 1、I have limited sample diluent. How should I handle samples requiring high dilution factors? Answer: We recommend performing a serial dilution. For example, if human serum requires a 1,000,000-fold dilution, you can use a three-step 100× dilution method as follows: Step 1: Take 2 uL of human serum and add it to 198 uL of sample diluent, mix thoroughly to obtain a 100-fold diluted sample. Step 2: Take 2 uL of the 100-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 10,000-fold diluted sample. Step 3: Take 2 uL of the 10,000-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 1,000,000-fold diluted sample. If further dilution is required, additional serial steps can be used. We do not recommend using any other solutions or water for dilution, except for the sample diluent we suggest. If your sample diluent is still insufficient, please contact our customer service for more sample diluent.