ECL Chemiluminescent Substrate Reagent Combo Pack servicebio G2161-200ML

$50.00
In stock
SKU
G2161-200ML

 

Product Information

Sensitive ECL Chemiluminescent Substrate Reagent Kit: 2×25 mL

Hypersensitive ECL Luminescence Substrate Reagent Kit: 2×25 mL

Product NameCat. No.
Spec.ECL Chemiluminescent Substrate Reagent Combo Pack
G2161-200MLECL Chemiluminescent Substrate Reagent Kit: 2×50 mL

Product Descrition/Introduction

This product is composed of three kinds of ECL chemiluminescent substrate reagent with different sensitivities: ECL chemiluminescent substrate reagent Kit, sensitive ECL chemiluminescent substrate reagent Kit, and hypersensitive ECL chemiluminescent substrate reagent Kit. The basic principle of ECL chemiluminescent substrate reagent is based on the chemiluminescence of luminol; it can react with horseradish peroxidase (HRP) coupled to the secondary antibody and emit light, which can be detected by X-ray film exposure or other imaging methods (e.g., fluorescence or chemiluminescence imaging equipment); the detection limits are nanogram, picogram, and femtogram, respectively, which can meet the needs of exposure experiments for different target proteins. Sensitive and hypersensitive ECL chemiluminescent substrate reagent can still detect signals at low sample concentrations, saving samples, and can still detect signals after incubation with the same low concentration of antibodies (primary and secondary), saving precious antibodies; the signal value of Sensitive ECL Chemiluminescent Substrate Reagent Kit is enhanced at least 10 times compared with ECL Chemiluminescent Substrate Reagent Kit, and the signal value of Hypersensitive ECL Luminescence Substrate Reagent Kit is enhanced at least 10 times compared with Sensitive ECL Chemiluminescent Substrate Reagent Kit.

Storage and Shipping Conditions

Ship with wet ice; Store at 2-8℃ away from light, valid for 12 months.

Product Components

Component NumberComponent
G2161-200MLG2161-1
ECL Chemiluminescent Substrate Reagent kitECL reagent A
50 mLG2161-2
ECL reagent B50 mL
G2161-3Sensitive ECL Chemiluminescent Substrate Reagent kit
Sensitive ECL reagent A25 mL
G2161-4Sensitive ECL reagent B
25 mLG2161-5
Hypersensitive ECL Luminescence Substrate Reagent kitHypersensitive ECL reagent A
25 mLG2161-6
Hypersensitive ECL reagent B25 mL
Manual1 pc

Assay Protocol/Procedures

1. Mix equal volumes of ECL A and ECL B of the same sensitivity to make the corresponding sensitivity of the ECL working solution at room temperature prior to use.

2. In Western blot experiment, PVDF membrane (or NC membrane) is incubated with secondary antibody, washed several times, and excess liquid is absorbed by filter paper. Place the membrane between two pieces of clean cling film (or PE gloves) and add ECL working solution to cover the surface of the membrane. This process should be done carefully to avoid air bubbles between the cling film and the PVDF membrane (or NC membrane).

3. After sufficient reaction, the excess ECL working solution was removed by filter paper or blotting paper, followed by either a pressurized plate or a fluorescence imager. 

4. The pressed film is developed and fixed with developing and fixing reagents (G2019 is recommended). Adjust the exposure conditions according to the luminous intensity.

Note

1. The pipette tips must be replaced during the liquid transferring process of ECL reagent A and ECL reagent B. Cross contamination of reagent A and reagent B will lead to the gradual failure.

2. Please wear gloves and use clean equipment such as tweezers to avoid contamination by exogenous proteins and metal ions during contact with the membrane.

3. Sodium azide inhibits HRP activity and all related reagents should be avoided.

4. In order to avoid affecting the accuracy of the results, please use up the ECL working solution within one day, do not leave it until the next day.

5. Please close the bottle tightly after use and keep it away from light to prevent failure; especially reagent B, which contains oxidants and is easy to be reduced and become ineffective.

6. ECL chemiluminescence substrate reagent kit selection refer to Table 1, primary antibody and secondary antibody recommended dilution ratio test data are from self-research antibody

7. ECL chemiluminescent assay common problems and solutions refer to Table II.

8. ECL reagent A and B are harmful to human body, pay attention to effective protection, avoid direct contact with the human body or inhalation of the respiratory tract.

9. For your safety and health, please wear safety glasses, gloves, or protective clothing.

Table 1: ECL chemiluminescence substrate reagent kit selection reference table

Product NameECL chemiluminescence substrate reagent kit
Sensitive ECL chemiluminescence substrate reagent kitHypersensitive ECL chemiluminescence substrate reagent kit
Cat. No.G2014
G2074G2020
Detection limitNanogram level
Picogram levelFemtogram level
Recommened dilution ratio of primary antibody (1 mg/mL storage solution)1:1000-1:5000
1:4000-1:100001:10000-30000
Recommened dilution ratio of secondary antibody (1 mg/mL storage solution)1:1000-1:6000
1:3000-1:600001:6000-150000
Characteristics and applicabilityWide range and applicability
Wide range and applicability, high sensitivity, medium abundance protein, saving antibodyExtremely sensitive, low abundance of protein, low or precious antibody titer

Table 2: Common problems and Solutions of ECL Chemiluminescence Detection

Switch to ECL chemiluminescence kit with higher sensitivity

Common ProblemPossible Cause
Possible SolutionHigh Background(High background or no specific bands)
Primary and secondary antibody dilution without using the correct buffer and concentrationAppropriately reduce the dilution ratio, reduce the concentration of primary and secondary antibodies
Blocking time or washing time is too short, or blocking solution is incorrectPhosphorylated protein detection must be blocked with BSA or protein-free blocking solution. The smaller the membrane pore size, the longer the blocking and elution time
The primary antibody is not fully incubated.Properly extend the incubation time (incubate overnight at 4℃)
Weak or No SignalPrimary and/or secondary antibody concentration too low
Increase the concentration of primary and secondary antibodiesLow protein abundance
Increase the sample volumeThe fluorescence is quenched rapidly and a hollow band (ghost band) appears.
The fluorescence of the target band is too strong, which consumes the luminous substrate quickly. After the substrate is consumed, it will appear to be white.Reduce the amount of protein or the amount of primary and secondary antibodies.
Brown or yellow bands appear on the membraneThe content of HRP enzyme in the target area is too rich, which produces a large number of free radicals, resulting in the oxidation inactivation of HRP enzyme.
Reduce the amount of protein samples or the amount of primary and secondary antibodies. 

For Research Use Only!