SV40LTA&E1A Residue DNA Detection Kit _ 41310ES yeasen

$955.00
In stock
SKU
41310ES50
Catalog No.SizePrice (USD)
41310ES5050 T$955.00
41310ES60100T$1,905.00

Product Description

This kit is designed for the quantitative detection of residual host cell DNA—specifically SV40 Large T Antigen (LTA) and Adenovirus E1A sequences—in biopharmaceutical products derived from host cells such as HEK293T. Utilizing probe-based real-time PCR (qPCR), the assay enables highly specific and rapid quantification of SV40 LTA and E1A residual DNA, with a limit of detection as low as 10¹ copies/μL. The kit is fully compatible with Yeasen’s Magnetic Bead–Based Residual DNA Sample Preparation Kits (Cat# 18461ES) for streamlined sample processing.

Features

  • Complies with regulations
  • – Fully validated; validation reports available.
  • High-quality reagents
  • – All components in-house developed; enzymes made in ultra-clean facility.
  • Highly sensitive
  • – Detection down to 10¹ copies/μL.
  • Highly reproducible
  • – Low within-run and between-run variability.
  • Highly specific
  • – Detects only SV40 LTA and E1A DNA—no cross-reactivity.
  • Built-in control
  • – Internal Control (IC) flags sample or reaction issues.

Components

  • Components No.
  • Name
  • 41310ES50(50 T)
  • 41310ES60(100 T)
  • 41310-A
  • SV40LTA&E1A qPCR
  • Mix
  • 0.75
  • mL
  • 1.5
  • mL
  • 41310-B
  • SV40LTA&E1A
  • Primer&Probe
  • M
  • ix
  • 200
  • μL
  • 400
  • μL
  • 41310-C
  • DNA
  • Dilution
  • Buffer
  • 2
  • ×
  • 1.8
  • mL
  • 4
  • ×
  • 1.8
  • mL
  • 41310-D
  • SV40LTA&E1A
  • DNA
  • Control
  • (nonliner)
  • 25
  • μL
  • 50
  • μL
  • 41310-E
  • SV40LTA&E1A
  • DNA
  • Control
  • (line
  • ar)
  • 25
  • μL
  • 50
  • μL
  • 41310-F
  • IC
  • 50
  • μL
  • 100
  • μL
  • *IC
  • Internal control.

Storage

This product should be stored at -25~-15 ℃ for 2 years. Both 41310-A and 41310-B should be stored protected from light. Applicable Instrument Models Include but not limited to: Bio-Rad: CFX96 Optic Module. Thermo Scientific: ABI 7500; ABI Quant Studio 5.

Figures

1. Detection Range SV40LTA: Linear range = 1.8 × 10¹ ~ 1.8 × 10⁵ copies/μL, R² = 1.000, amplification efficiency = 100.25%, CV < 15% across all concentrations. E1A: Linear range = 1.8 × 10¹ ~ 1.8 × 10⁵ copies/μL, R² = 1.000, amplification efficiency = 100.25%, CV < 15% across all concentrations.

Figure 1. SV40LTA standard curve (left) and amplification plot (right)

Figure 2. E1A standard curve (left) and amplification plot (right) 2. Limit of Quantitation (LOQ) SV40LTA & E1A DNA at concentrations of 18, 9, 4.5, 2.25, and 1.8 copies/μL were tested in 10 replicates each. At ≥4.5 copies/μL, CVs were <20%, establishing the LOQ as 4.5 copies/μL. 3 . qPCR detection of SV40LTA (lift) and E1A(right) at 4.5 copies/μL Replicate Analyte SV40LTA (copies/μL) E1A (copies/μL) Quantity Recovery Quantity Recovery 1 4.66 103.61% 4.87 108.21% 2 4.33 96.29% 4.15 92.26% 3 4.49 99.72% 4.63 102.88% 4 5.08 112.97% 4.86 107.99% 5 6.26 139.11% 5.67 125.93% 6 5.46 121.26% 4.97 110.42% 7 4.79 106.34% 5.50 122.22% 8 5.57 123.83% 5.00 111.20% 9 5.09 113.18% 5.55 123.28% 10 4.62 102.62% 4.97 110.43% Mean 5.04 5.02 CV% 11.73% 9.13%

Safety Data Sheet

  • 40310
  • _MSDS_HB
  • 260
  • 203
  • _EN.PDF

Manuals

  • 40310
  • _Manual_Ver.E
  • N
  • 20260
  • 203
  • .pdf

Reviews

Write Your Own Review
You're reviewing:SV40LTA&E1A Residue DNA Detection Kit _ 41310ES yeasen
Your Rating