Human Ficolin 3(FCN3) ELISA Kit CSB-E13104h CUSABIO

$50.00
In stock
SKU
CSB-E13104h

Product Details

Target Nameficolin (collagen/fibrinogen domain containing) 3 (Hakata antigen)
Uniprot No.O75636
SpeciesHomo sapiens (Human)
StorageStore at 2-8°C. Please refer to protocol.
Sensitivity1.95 ng/mL
Troubleshooting and FAQsELISA kit FAQs
Lead Time3-5 working days after you place the order, and it takes another 3-5 days for delivery via DHL or FedEx.
Associated namesFCN3 ELISA Kit; FCNH ELISA Kit; HAKA1 ELISA Kit; Ficolin-3 ELISA Kit; Collagen/fibrinogen domain-containing lectin 3 p35 ELISA Kit; Collagen/fibrinogen domain-containing protein 3 ELISA Kit; Hakata antigen ELISA Kit
AbbreviationFCN3
Sample Typesserum, plasma, cell culture supernates, tissue homogenates
Detection Range7.8 ng/mL-500 ng/mL
Assay Time1-5h
Sample Loading Volume50-100ul
Detection Wavelength450 nm
Research AreaImmunology
Assay Principlequantitative
MeasurementSandwich
Precisionheaders: Intra-assay Precision (Precision within an assay): CV%<8%; rows: Intra-assay Precision (Precision within an assay): CV%<8%: Intra-assay Precision (Precision within an assay): CV%<8%; 1: Three samples of known concentration were tested twenty times on one plate to assess.; Intra-assay Precision (Precision within an assay): CV%<8%: Inter-assay Precision (Precision between assays): CV%<10%; 1: Three samples of known concentration were tested in twenty assays to assess.;
Linearityheaders: To assess the linearity of the assay, samples were spiked with high concentrations of human FCN3 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.; rows: To assess the linearity of the assay, samples were spiked with high concentrations of human FCN3 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.: To assess the linearity of the assay, samples were spiked with high concentrations of human FCN3 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.; 2: Sample; 3: Serum(n=4); 1: 1:100; 2: Average %; 3: 99; 1: Range %; 2: 88-104; 1: 1:200; 2: Average %; 3: 101; 1: Range %; 2: 91-105; 1: 1:400; 2: Average %; 3: 88; 1: Range %; 2: 83-94; 1: 1:800; 2: Average %; 3: 93; 1: Range %; 2: 87-97
Recoveryheaders: The recovery of human FCN3 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.; rows: The recovery of human FCN3 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.: The recovery of human FCN3 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.; ; 1: Sample Type; 2: Average % Recovery; 3: Range; 1: Serum (n=5); 2: 107; 3: 98-114; 1: EDTA plasma (n=4); 2: 100; 3: 95-104; ;
Typical Dataheaders: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.; rows: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.; ; 1: ng/ml OD1 OD2 Average Corrected 500 2.817 2.721 2.769 2.650 250 2.312 2.242 2.277 2.158 125 1.530 1.578 1.554 1.435 62.5 0.778 0.764 0.771 0.652 31.2 0.408 0.414 0.411 0.292 15.6 0.253 0.243 0.248 0.129 7.8 0.167 0.173 0.170 0.051 0 0.117 0.121 0.119; 2: ng/ml; 3: OD1; 4: OD2; 5: Average; 6: Corrected; 9: 500; 10: 2.817; 11: 2.721; 12: 2.769; 13: 2.650; 16: 250; 17: 2.312; 18: 2.242; 19: 2.277; 20: 2.158; 23: 125; 24: 1.530; 25: 1.578; 26: 1.554; 27: 1.435; 30: 62.5; 31: 0.778; 32: 0.764; 33: 0.771; 34: 0.652; 37: 31.2; 38: 0.408; 39: 0.414; 40: 0.411; 41: 0.292; 44: 15.6; 45: 0.253; 46: 0.243; 47: 0.248; 48: 0.129; 51: 7.8; 52: 0.167; 53: 0.173; 54: 0.170; 55: 0.051; 58: 0; 59: 0.117; 60: 0.121; 61: 0.119; 1: ng/ml; 2: OD1; 3: OD2; 4: Average; 5: Corrected; 1: 500; 2: 2.817; 3: 2.721; 4: 2.769; 5: 2.650; 1: 250; 2: 2.312; 3: 2.242; 4: 2.277; 5: 2.158; 1: 125; 2: 1.530; 3: 1.578; 4: 1.554; 5: 1.435; 1: 62.5; 2: 0.778; 3: 0.764; 4: 0.771; 5: 0.652; 1: 31.2; 2: 0.408; 3: 0.414; 4: 0.411; 5: 0.292; 1: 15.6; 2: 0.253; 3: 0.243; 4: 0.248; 5: 0.129; 1: 7.8; 2: 0.167; 3: 0.173; 4: 0.170; 5: 0.051; 1: 0; 2: 0.117; 3: 0.121; 4: 0.119
ELISA Data AnalysisELISA Standard Curve & Curve Expert software
Shelf Life6 months
DescriptionThis Human FCN3 ELISA Kit was designed for the quantitative measurement of Human FCN3 protein in serum, plasma, cell culture supernates, tissue homogenates. It is a Sandwich ELISA kit, its detection range is 7.8 ng/mL-500 ng/mL and the sensitivity is 1.95 ng/mL.

MDSD

MSDS

Reviews

Write Your Own Review
You're reviewing:Human Ficolin 3(FCN3) ELISA Kit CSB-E13104h CUSABIO
Your Rating