Human RNA-binding protein FUS (FUS/TLS) ELISA kit CSB-E17376h CUSABIO
$50.00
In stock
SKU
CSB-E17376h
Product Details
| Target Name | fusion (involved in t(12;16) in malignant liposarcoma) |
| Uniprot No. | P35637 |
| Species | Homo sapiens (Human) |
| Storage | Store at 2-8°C. Please refer to protocol. |
| Sensitivity | 3.9 pg/mL |
| Troubleshooting and FAQs | ELISA kit FAQs |
| Lead Time | 3-5 working days after you place the order, and it takes another 3-5 days for delivery via DHL or FedEx. |
| Associated names | 75 kDa DNA pairing protein ELISA Kit; 75 kDa DNA-pairing protein ELISA Kit; ALS6 ELISA Kit; Amyotrophic lateral sclerosis 6 ELISA Kit; fus ELISA Kit; FUS CHOP ELISA Kit; Fus like protein ELISA Kit; FUS_HUMAN ELISA Kit; FUS1 ELISA Kit; Fused in sarcoma ELISA Kit; Fusion (involved in t(12,16) in malignant liposarcoma) ELISA Kit; Fusion derived from t(12,16) malignant liposarcoma ELISA Kit; Fusion gene in myxoid liposarcoma ELISA Kit; Heterogeneous nuclear ribonucleoprotein P2 ELISA Kit; hnRNP P2 ELISA Kit; hnRNPP2 ELISA Kit; Oncogene FUS ELISA Kit; Oncogene TLS ELISA Kit; POMp75 ELISA Kit; RNA binding protein FUS ELISA Kit; RNA-binding protein FUS ELISA Kit; TLS ELISA Kit; TLS CHOP ELISA Kit; Translocated in liposarcoma ELISA Kit; Translocated in liposarcoma protein ELISA Kit |
| Abbreviation | FUS |
| Sample Types | serum, plasma, cell lysates |
| Detection Range | 15.6 pg/mL-1000 pg/mL |
| Assay Time | 1-5h |
| Sample Loading Volume | 50-100ul |
| Detection Wavelength | 450 nm |
| Research Area | Signal Transduction |
| Assay Principle | quantitative |
| Measurement | Sandwich |
| Precision | headers: Intra-assay Precision (Precision within an assay): CV%<8%; rows: Intra-assay Precision (Precision within an assay): CV%<8%: Intra-assay Precision (Precision within an assay): CV%<8%; 1: Three samples of known concentration were tested twenty times on one plate to assess.; Intra-assay Precision (Precision within an assay): CV%<8%: Inter-assay Precision (Precision between assays): CV%<10%; 1: Three samples of known concentration were tested in twenty assays to assess. |
| Linearity | headers: To assess the linearity of the assay, samples were spiked with high concentrations of human FUS/TLS in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.; rows: To assess the linearity of the assay, samples were spiked with high concentrations of human FUS/TLS in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.: To assess the linearity of the assay, samples were spiked with high concentrations of human FUS/TLS in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.; 2: Sample; 3: Serum(n=4); 1: 1:1; 2: Average %; 3: 100; 1: Range %; 2: 98-102; 1: 1:2; 2: Average %; 3: 102; 1: Range %; 2: 95-108; 1: 1:4; 2: Average %; 3: 103; 1: Range %; 2: 99-107; 1: 1:8; 2: Average %; 3: 93; 1: Range %; 2: 88-97 |
| Recovery | headers: The recovery of human FUS/TLS spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.; rows: The recovery of human FUS/TLS spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.: The recovery of human FUS/TLS spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.; 1: Sample Type; 2: Average % Recovery; 3: Range; 1: Serum (n=5); 2: 95; 3: 90-100; 1: EDTA plasma (n=4); 2: 101; 3: 94-108 |
| Typical Data | headers: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.; rows: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.; ; ; 1: pg/ml; 2: OD1; 3: OD2; 4: Average; 5: Corrected; 1: 1000; 2: 2.546; 3: 2.634; 4: 2.590; 5: 2.432; 1: 500; 2: 2.001; 3: 1.967; 4: 1.984; 5: 1.826; 1: 250; 2: 1.314; 3: 1.268; 4: 1.291; 5: 1.133; 1: 125; 2: 0.635; 3: 0.629; 4: 0.632; 5: 0.474; 1: 62.5; 2: 0.426; 3: 0.421; 4: 0.424; 5: 0.266; 1: 31.2; 2: 0.285; 3: 0.293; 4: 0.289; 5: 0.131; 1: 15.6; 2: 0.227; 3: 0.214; 4: 0.221; 5: 0.063; 1: 0; 2: 0.161; 3: 0.155; 4: 0.158 |
| ELISA Data Analysis | ELISA Standard Curve & Curve Expert software |
| Shelf Life | 6 months |
MDSD