Mouse Interleukin 4,IL-4 ELISA KIT CSB-E04634m-IS CUSABIO
$50.00
In stock
SKU
CSB-E04634m-IS
Product Details
| Uniprot No. | P07750 |
| Species | Mus musculus (Mouse) |
| Storage | Store at 2-8°C. Please refer to protocol. |
| Sensitivity | 1.56 pg/ml |
| Troubleshooting and FAQs | ELISA kit FAQs |
| Lead Time | 3-5 working days after you place the order, and it takes another 3-5 days for delivery via DHL or FedEx. |
| Associated names | Il4 ELISA kit; Il-4Interleukin-4 ELISA kit; IL-4 ELISA kit; B-cell IgG differentiation factor ELISA kit; B-cell growth factor 1 ELISA kit; B-cell stimulatory factor 1 ELISA kit; BSF-1 ELISA kit; IGG1 induction factor ELISA kit; Lymphocyte stimulatory factor 1 ELISA kit |
| Abbreviation | IL4 |
| Sample Types | serum, plasma, tissue homogenates |
| Detection Range | 6.25 pg/ml-400 pg/ml |
| Assay Time | 1-5h |
| Sample Loading Volume | 50-100ul |
| Detection Wavelength | 450 nm |
| Research Area | Immunology |
| Assay Principle | quantitative |
| Measurement | Sandwich |
| Precision | headers: Intra-assay Precision (Precision within an assay): CV%<8%; rows: Intra-assay Precision (Precision within an assay): CV%<8%: Intra-assay Precision (Precision within an assay): CV%<8%; 1: Three samples of known concentration were tested twenty times on one plate to assess.; Intra-assay Precision (Precision within an assay): CV%<8%: Inter-assay Precision (Precision between assays): CV%<10%; 1: Three samples of known concentration were tested in twenty assays to assess. |
| Linearity | headers: To assess the linearity of the assay, samples were spiked with high concentrations of mouse IL-4 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.; rows: To assess the linearity of the assay, samples were spiked with high concentrations of mouse IL-4 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.: To assess the linearity of the assay, samples were spiked with high concentrations of mouse IL-4 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.; 2: Sample; 3: Serum(n=4); 1: 1:1; 2: Average %; 3: 89; 1: Range %; 2: 82-96; 1: 1:2; 2: Average %; 3: 93; 1: Range %; 2: 89-98; 1: 1:4; 2: Average %; 3: 100; 1: Range %; 2: 92-109; 1: 1:8; 2: Average %; 3: 93; 1: Range %; 2: 86-98 |
| Recovery | headers: The recovery of mouse IL-4 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.; rows: The recovery of mouse IL-4 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.: The recovery of mouse IL-4 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.; 1: Sample Type; 2: Average % Recovery; 3: Range; 1: Serum (n=5); 2: 92; 3: 86-98; 1: EDTA plasma (n=4); 2: 96; 3: 90-100 |
| Typical Data | headers: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.; rows: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.; ; ; 1: pg/ml; 2: OD1; 3: OD2; 4: Average; 5: Corrected; 1: 400; 2: 3.058; 3: 2.934; 4: 2.996; 5: 2.853; 1: 200; 2: 2.483; 3: 2.327; 4: 2.405; 5: 2.261; 1: 100; 2: 1.612; 3: 1.628; 4: 1.620; 5: 1.477; 1: 50; 2: 0.985; 3: 0.971; 4: 0.978; 5: 0.835; 1: 25; 2: 0.564; 3: 0.577; 4: 0.570; 5: 0.427; 1: 12.5; 2: 0.335; 3: 0.323; 4: 0.329; 5: 0.186; 1: 6.25; 2: 0.251; 3: 0.239; 4: 0.245; 5: 0.101; 1: 0; 2: 0.142; 3: 0.145; 4: 0.143 |
| ELISA Data Analysis | ELISA Standard Curve & Curve Expert software |
| Shelf Life | 6 months |
| Description | This Mouse IL-4 ELISA Kit provides quantitative measurement of interleukin-4 in Mus musculus samples, supporting research into Th2-mediated immune responses, allergic inflammation, and alternative macrophage activation. Because IL-4 is often present at low picogram-level concentrations in vivo yet can rise sharply during Th2-polarized responses or allergic challenge, accurate quantification across this dynamic range is critical for meaningful experimental readouts. Detection Range: The 6.25–400 pg/ml range spans the concentrations typically observed from baseline circulating IL-4 in naïve mice through the elevated levels found during helminth infection, OVA-induced airway inflammation, or Th2-skewed in vitro cultures, minimizing the need for extensive sample dilution in most disease models. Sensitivity: At 1.56 pg/ml, the kit detects the characteristically low IL-4 levels present in unstimulated mouse serum or early-phase allergic responses, where this cytokine is notoriously difficult to capture due to rapid receptor-mediated consumption. Sample Compatibility: Validation across serum, plasma, and tissue homogenates enables researchers to correlate systemic IL-4 levels with local tissue expression—for example, comparing circulating cytokine to lung homogenate concentrations in asthma models. Assay Efficiency: The 50–100 µl sample volume and 1–5 hour protocol accommodate the limited serum volumes obtainable from individual mice, preserving samples for parallel cytokine measurements without requiring blood pooling. This kit is well-suited for studies of allergic asthma, anti-helminth immunity, and M2 macrophage polarization. |