Human Cross-linked Carboxy-terminal telopeptide of type Ⅰ collagen, CTX-I ELISA Kit CSB-E11224h CUSABIO
$50.00
In stock
SKU
CSB-E11224h
Product Details
| Target Name | Cross-linked Carboxy-terminal telopeptide of type Ⅰ collagen, CTX-I |
| Species | Homo sapiens (Human) |
| Storage | Store at 2-8°C. Please refer to protocol. |
| Sensitivity | 0.156 ng/mL |
| Troubleshooting and FAQs | ELISA kit FAQs |
| Lead Time | 3-5 working days after you place the order, and it takes another 3-5 days for delivery via DHL or FedEx. |
| Associated names | Cross-linked Carboxy-terminal telopeptide of type 1 collagen, CTX-1,Cross-linked Carboxy-terminal telopeptide of type I collagen, CTX-I |
| Abbreviation | CTX-I |
| Sample Types | serum, plasma, tissue homogenates |
| Detection Range | 0.625 ng/mL-40 ng/mL |
| Assay Time | 1-5h |
| Sample Loading Volume | 50-100ul |
| Detection Wavelength | 450 nm |
| Research Area | Others |
| Assay Principle | quantitative |
| Measurement | Sandwich |
| Precision | headers: Intra-assay Precision (Precision within an assay): CV%<8%; rows: Intra-assay Precision (Precision within an assay): CV%<8%: Intra-assay Precision (Precision within an assay): CV%<8%; 1: Three samples of known concentration were tested twenty times on one plate to assess.; Intra-assay Precision (Precision within an assay): CV%<8%: Inter-assay Precision (Precision between assays): CV%<10%; 1: Three samples of known concentration were tested in twenty assays to assess.; |
| Linearity | headers: To assess the linearity of the assay, samples were spiked with high concentrations of human CTX-I in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.; rows: To assess the linearity of the assay, samples were spiked with high concentrations of human CTX-I in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.: To assess the linearity of the assay, samples were spiked with high concentrations of human CTX-I in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.; 2: Sample; 3: Serum(n=4); 1: 1:1; 2: Average %; 3: 88; 1: Range %; 2: 83-95; 1: 1:2; 2: Average %; 3: 95; 1: Range %; 2: 91-98; 1: 1:4; 2: Average %; 3: 97; 1: Range %; 2: 90-103; 1: 1:8; 2: Average %; 3: 96; 1: Range %; 2: 91-101 |
| Recovery | headers: The recovery of human CTX-I spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.; rows: The recovery of human CTX-I spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.: The recovery of human CTX-I spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.; 1: Sample Type; 2: Average % Recovery; 3: Range; 1: Serum (n=5); 2: 85; 3: 81-92; 1: EDTA plasma (n=4); 2: 96; 3: 93-106; ; |
| Typical Data | headers: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.; rows: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.; 1: ng/ml OD1 OD2 Average Corrected 40 2.995 2.960 2.978 2.838 20 2.557 2.570 2.564 2.424 10 1.666 1.765 1.716 1.576 5 0.839 0.886 0.863 0.723 2.5 0.491 0.524 0.508 0.368 1.25 0.263 0.251 0.257 0.117 0.625 0.201 0.212 0.207 0.067 0 0.138 0.142 0.140; 2: ng/ml; 3: OD1; 4: OD2; 5: Average; 6: Corrected; 8: 40; 9: 2.995; 10: 2.960; 11: 2.978; 12: 2.838; 14: 20; 15: 2.557; 16: 2.570; 17: 2.564; 18: 2.424; 20: 10; 21: 1.666; 22: 1.765; 23: 1.716; 24: 1.576; 26: 5; 27: 0.839; 28: 0.886; 29: 0.863; 30: 0.723; 32: 2.5; 33: 0.491; 34: 0.524; 35: 0.508; 36: 0.368; 38: 1.25; 39: 0.263; 40: 0.251; 41: 0.257; 42: 0.117; 44: 0.625; 45: 0.201; 46: 0.212; 47: 0.207; 48: 0.067; 50: 0; 51: 0.138; 52: 0.142; 53: 0.140; 1: ng/ml; 2: OD1; 3: OD2; 4: Average; 5: Corrected; 1: 40; 2: 2.995; 3: 2.960; 4: 2.978; 5: 2.838; 1: 20; 2: 2.557; 3: 2.570; 4: 2.564; 5: 2.424; 1: 10; 2: 1.666; 3: 1.765; 4: 1.716; 5: 1.576; 1: 5; 2: 0.839; 3: 0.886; 4: 0.863; 5: 0.723; 1: 2.5; 2: 0.491; 3: 0.524; 4: 0.508; 5: 0.368; 1: 1.25; 2: 0.263; 3: 0.251; 4: 0.257; 5: 0.117; 1: 0.625; 2: 0.201; 3: 0.212; 4: 0.207; 5: 0.067; 1: 0; 2: 0.138; 3: 0.142; 4: 0.140 |
| ELISA Data Analysis | ELISA Standard Curve & Curve Expert software |
| Shelf Life | 6 months |
| Description | This Human CTX-I ELISA Kit was designed for the quantitative measurement of Human CTX-I protein in serum, plasma, tissue homogenates. It is a Sandwich ELISA kit, its detection range is 0.625 ng/mL-40 ng/mL and the sensitivity is 0.156 ng/mL. |
MDSD