| Product name | Human EIF2S1 ELISA Kit |
| Synonyms | EIF2S1,EIF2S1/EIF2A,EIF 2,eIF 2 alpha,EIF 2A |
| Reactivity | Human |
| Host / Isotype | United States |
| Tests | 1 X 96 well plate |
| Sample type | Cell lysate |
| Assay type | Sandwich |
| Sensitivity | 0.04 ng/mL |
| Range | 0.156-10 ng/mL |
| Tested applications | Sandwich ELISA |
| Gene ID (NCBI) | 1965 |
| Sample Type | Average Range |
| Cell lysate | 86% 83%-90% |
| Sample | n mean ( ng/mL ) SD CV% |
| 1 | 16 4.68 0.16 3.41 |
| 2 | 16 1.10 0.03 2.38 |
| 3 | 16 0.57 0.01 2.52 |
| Storage Instructions | All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. |
EIF2S1/eIF2α (eukaryotic translation initiation factor 2 subunit alpha) is a subunit of the EIF2 complex, which facilitates the placement of an initiator tRNA (methionyl-tRNAi) onto the P site of the 40S ribosomal subunit during the translation initiation of cytoplasmic mRNAs in eukaryotic cells. EIF2 complex activity is regulated by EIF2S1 phosphorylation. EIF2S1 phosphorylation transiently attenuates the translation of most mRNAs but promotes the translation of selected mRNAs, including the transcripts of TF (transcription factor) genes, nutrient metabolism-related genes , a phosphatase regulatory subunit gene (Ppp1r15a/Gadd34), and cellular adaptation-related genes (Ibtk/Ibtk and Cpeb4). Properties Storage Instructions All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. Synonyms EIF2S1,EIF2S1/EIF2A,EIF 2,eIF 2 alpha,EIF 2A FAQ 1、I have limited sample diluent. How should I handle samples requiring high dilution factors? Answer: We recommend performing a serial dilution. For example, if human serum requires a 1,000,000-fold dilution, you can use a three-step 100× dilution method as follows: Step 1: Take 2 uL of human serum and add it to 198 uL of sample diluent, mix thoroughly to obtain a 100-fold diluted sample. Step 2: Take 2 uL of the 100-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 10,000-fold diluted sample. Step 3: Take 2 uL of the 10,000-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 1,000,000-fold diluted sample. If further dilution is required, additional serial steps can be used. We do not recommend using any other solutions or water for dilution, except for the sample diluent we suggest. If your sample diluent is still insufficient, please contact our customer service for more sample diluent.